1. STOP! Read all the above safety information before proceeding.
2. Set the receiver switch to the "ON" position (see Fig. 28).
NOTE: When used as a vented decorative appliance, use of the
thermostat function is prohibited—operate manually only.
3. Turn the control knob clockwise
(see Fig. 28).
4. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in
the safety information above. If you don't smell gas, go to the
next step.
5. Push in slightly and turn the control knob counterclockwise
to the "PILOT" position (see Fig. 28). Depress the control knob.
6. With the control knob depressed, push down on the ignitor
button until the pilot lights. The pilot is located behind log #3
near the center of the burner (see Fig. 29).
7. Keep the control knob depressed for (30) seconds after the
pilot lights. Release the control knob.
• If the control knob does not pop up when released, stop and
immediately call a qualified service technician or gas supplier.
• If the pilot goes out, repeat steps 3 through 7. Wait (1) minute
before attempting to light the pilot again. If after several tries the
pilot still goes out, turn the gas control knob clockwise
the "OFF" position and call a qualified service technician.
8. Turn the control knob counterclockwise
9. To use the included thermostatic remote control, set the
receiver switch to the "REMOTE" position (see Fig. 30). Press the
"ON" button to turn on the remote to ignite the main burner.
Refer to the remote control instruction manual on page 25 for
the "MODE" and "SET" functions.
WARNING
WARNING
1. Set the thermostat to the lowest setting.
2. Press the "OFF" button on the remote control.
3. Push in slightly and turn the control knob clockwise
©2017 Pinnacle Climate Technologies
Operation—REM-L240CLR-F / REM-L240CNR-F

LIGHTING INSTRUCTIONS

The fireplace screen must be in place while the heater is in operation.
Any glass doors must be completely opened while the heater is operating.
TO TURN OFF GAS TO THE HEATER
to the "OFF" position
to
to the "ON" position.
to the "OFF" position.