Heater Clearances - Pinnacle Climate Remington REM-L180ALT-F Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

IMPORTANT: Vent-free heaters add moisture to the air, which is beneficial. However, if this heater is installed
in areas without adequate ventilation, mildew may form from too much moisture in the air. See AIR FOR
COMBUSTION AND VENTILATION, pages
CHECK GAS TYPE: Be sure your gas supply is right for your heater. If the supply is not correct, do not install
the heater. Contact the place where this heater was purchased for a heater appropriate for your gas supply.
NOTICE: State or local codes may only allow operation of this appliance in a vented configuration. Check
your state or local codes.
Log Size
18 in.
24 in.

HEATER CLEARANCES

CAUTION
For convenience and efficiency, install the heater with these points in mind:
• Provide easy access for operation, inspection and service.
• Install the heater in the coldest part of the room.
If this heater is installed directly on carpeting, tile, or other combustible material, other than wood flooring,
the heater must be installed on a metal or wood panel that extends the heater's full width and depth.
Minimum Clearances for Side Combustible Material, Side Wall, and Ceiling:
A. Clearances from the side of the heater cabinet to any combustible material and wall must follow the
specifications listed in the below table.
B. Clearances from the top of the heater opening to the ceiling must not be less than 36".
WARNING
18 in.
24 in.
WARNING
©2017 Pinnacle Climate Technologies
Installation (cont.)
7 through
Log Sizing Requirements
Height
24 in
24 in.
If you install the heater in a home garage, a.) ensure the heater pilot and burner are at
least 18" above the floor and, b.) locate the heater where moving vehicles will not hit it.
Maintain the minimum clearances. If possible, provide greater clearances from the
floor, ceiling, and adjoining wall than required.
Minimum Fireplace Clearance to Combustible Materials
Log Size
Seal any fresh air vents or ash clean-out doors located on the floor or wall of the fireplace
with a heat-resistant sealant—this prevents drafting caused by pilot outage or sooting.
Do not seal the chimney flue damper.
9.
Minimum Firebox Size
Depth
14 in.
14 in.
Side Wall
16 in.
16 in.
11
Front Width
28 in.
20 in.
32 in.
22 in.
Ceiling
36 in.
36 in.
Vent-Free Gas Log Heater User Manual
Rear Width
Tabla de contenido
loading

Tabla de contenido