8) Clean the dirty and dusty in the unit.
Check the unit inner for dusty and dirty and clean it.
Check the muffler and the places near the engine for trash or flammable materials and clean them.
Check the intake and exhaust port if clogged by the dirty. Clean it, if necessary.
9) Electrical connection with load
a) Make sure that load does not exceed the unit power capacity, then connect electrical
connections properly.
b) connect output cable as per regulated wire diameter, the wire diameter should 2 take the load
flow of MM as 3-5A.
c) The output cable is shorter is better, the overlong output wire will effected the
voltage decline so generator should be closed to the loading center when install.

3. SAFETY PRECAUTIONS FOR SERVICING

1. The installation and maintenance work should be operated by professional maintainer.
2. Always wear a face shield, rubber gloves and protective clothing when working on the unit.
3. Do not touch the generator unit or any part of load with your bare hands or wet hands.
4. Keep hands, hair, loose clothing, and tools away from moving parts, such as fans, belts and
rotors.
5. The exhaust gas and fuel of generator are poisonous. Please operate carefully.
6. Stop engine and let it cool off before checking or adding fuel.
7. Never smoking and be far away from any flame when filling the fuel.
8. Observe correct polarity (+& -) on batteries.
9. Fix the battery with pressure plate when the generator running.
10. Use equipment of adequate capacity to lift and support unit and components.
11. Don't pour waste oil into the sewer or the river to prevent environment pollution.
The exhaust oil from generator must be stored in container. To deal with bad matter, such as fuel,
oil cooling water, solvent, filter and battery, according to the law.
12. Shut down the power after removing the battery cathodic wire when checking and maintaining
generator. Connect battery anode then cathode.
13. It is limited to use the generator in the high-hazard risk area.

4. WARM-UP PROCEDURE

1. Check the fuel before every start.
2. Check if the engine oil reaches the scale of stipulating.