INSTALLING ACCESSORIES

9.1
Flue (fig. 12)
The heater has a flue stack connection.
1. Push a T-piece (A) directly over the
connection (B).
2. Push the flue pipe (C) on the T-piece.
3. Use three screws to secure the flue pipe
to the T-piece.
Caution
The flue must meet the following
requirements.
The flue must point upwards.
The flue (or any part of it) may not be
positioned horizontally. A 45° angle is
acceptable.
It is not allowed to lengthen the flue
connection horizontally.
When a pipe is used at 45°, pipe pieces
of at least 1 m must be fitted in front of
and at the back of the slanting pipe.
The flue must stick out at least 0.5 m
above the apex of the building.
Keep the vertical part at the back of the
heater as long as possible before leading
it outside through the wall.
4. Fit the following pipe pieces.
5. Place a cap (D) on the end of the flue.
28