INSTALLING ACCESSORIES
9.1
Flue (fig. 12)
The heater has a flue stack connection.
1. Push a T-piece (A) directly over the
connection (B).
2. Push the flue pipe (C) on the T-piece.
3. Use three screws to secure the flue pipe
to the T-piece.
Caution
The flue must meet the following
requirements.
•
The flue must point upwards.
•
The flue (or any part of it) may not be
positioned horizontally. A 45° angle is
acceptable.
•
It is not allowed to lengthen the flue
connection horizontally.
•
When a pipe is used at 45°, pipe pieces
of at least 1 m must be fitted in front of
and at the back of the slanting pipe.
•
The flue must stick out at least 0.5 m
above the apex of the building.
•
Keep the vertical part at the back of the
heater as long as possible before leading
it outside through the wall.
4. Fit the following pipe pieces.
5. Place a cap (D) on the end of the flue.
28
9.2
/i
BIO ENERGY 2
150 mm
10
For the EC declaration of conformity, go to
www.thermobile.nl.
40.020.953 - rev. 05 - 2015
Diameter of flue
EC DECLARATION OF
CONFORMITY
Bio Energy series