Fault
The flame extin-
guishes directly after
ignition.
The heater makes a
humming sound.
There is unburnt veg-
etable oil or biodiesel
on the burner dish.
Record the maintenance details in table A in
the appendix of this manual.
7
SPARE PARTS
Before use we advise you to have spare parts
in store, see table B in the appendix of this
manual.
8
TECHNICAL INFORMATION
•
See for technical specifications table C in
the appendix of this manual.
Bio Energy series
Cause
15 The flue draught is too
low.
16 There is too much vege-
table oil or biodiesel at
start-up.
40.020.953 - rev. 05 - 2015
Solution
Check all connections in the
flue.
Check whether the draught
regulator is off.
Check the flue for blockage.
Reduce the number of
bends.
Raise the flue.
Insulate the flue outside the
building.
Check the flue, see "flue".
Reduce the quantity of vege-
table oil or biodiesel with a
new start-up.
Low temperature for single
walled flue, for instance in
case of frost.
The sound will stop when the
temperature rises.
See faults: 2, 11, 12, 13 and
14.