6. POWER UNIT INSTALLATION

6.1 LOCATING THE POWER UNIT

• Locate the power unit away from the general living area in an accessible
location for cleaning and maintenance.
• Locate the power unit within 6 feet of a grounded electrical outlet. The power
unit requires a 120 VAC power source.
• Do not locate the power unit close to a source of extreme heat (i.e.: water
heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).
• If the power unit is located in a closet or a small utility room, make sure the area
is well-ventilated (i.e.: with door louvers).
NOTE: Visit www.nutone.com for the central vacuum system installation instructions.
6.2 MOUNTING POWER UNIT
Ensure to assemble the wall mounting
bracket with the screws directly onto a
wall stud for a solid installation.
1. Carefully remove debris pail from power
unit. Make sure bag is properly installed in
power unit. Remove accessories and
installation kit. Securely reinstall pail.
2. Install the 3-way elbow on the back of the
power unit and press firmly (do not glue).
Remove the plastic cap from the inlet
opening only if your installation requires the
connection into both inlets.
AO0034
3. Install mounting bracket on a wall stud within
6 feet of a grounded electrical outlet, at the
distances specified on illustration at right.
Ensure that wall between mounting bracket
and inlet is straight and leveled.
CAUTION
3-
WAY ELBOW
DO NOT GLUE
R
PLASTIC CAP
(
IF NEED BE
EMOVE
)
- 6 -
MINIMUM WALL CLEARANCE
DIMENSIONS
PVC TUBING STRAP
INLET
TOP VIEW
CEILING
12"
MINIMUM TO CEILING
INLET
30"
50"
FRONT VIEW
18"
MINIMUM ABOVE FLOOR
FLOOR
AD0043A
14"
.
MIN
INLET
EXHAUST
WALL BRACKET
EXHAUST
12"
INLET