4.9 Decimal point (frequency meter)
4.10 Display mode (frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min
4.11 Max. time to wait until „0" is displayed
(frequency meter)
This parameter indicates, how long it takes,
when measuring is active, until „0" is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s

4.12 End of programming

The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Page 6 | ENG
Electronic display counter with
2 totalising ranges
Codix 54U: basic operating mode
1. Description
• 6-digit dislay counter with Reset function
• Red LED display, character height 14 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
2. Inputs
INP A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can be
adjusted individually for Counter 1 and Counter
2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of totaliser 1 and the display of
totaliser 2. Press the key briefly to display for 2
seconds the current function ("total1" or "total2").
If, during this period of time, the right key is
pressed a second time, the device switches to
the current function and displays a confirmation
("total1" or "total2") for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory setting