3.3 Mounting
- Make sure that the pivot of foundation box is well greased. Lay down
the ball (A) end insert drive rod (B) after fitting release system (picture
5).
- Fit gate bracket plate (C) through its pivot in the drive rod (B) (picture
5).
- Place gate leaf between upper hinge and plate of gate bracket (hinge
and pivot of gate bracket plate should be perfectly aligned).
- Weld carefully bracket plate (C) on the leaf.
- Fit adjusting open position bolt (D) (picture 6) M10X30 and relevant
nut.
- Fit EIM2 operator inside the foundation box (picture 6).
- Screw on pulling lever (B) adjusting bolt M10x60 (E) and relevant nut
(picture 6).
- Fit joint lever (F) (picture 6.
- ATTENTION: joint lever (F) must be fitted as shown in picture 6.
Should it be difficoult to fit, operate electrically the reducer.
3.4 Adjustment of mechanical stopper
The HIDDY 350D system requires no floor stops or other accessories
as the gate travel limit is determined by means of set screws located
internally of the box.
Access to the screws is gained by lifting the cover.
- To adjust the travel limit for the opening movement of the gate, simply
turn the screw (D) left or right as appropriate, then secure the lock nut
to prevent the screw from slipping out of position subsequently (Fig. 5).
Same adjusting must be done also on bolt (E) for closing, in order to let the
mechanism block again when unblocked (Fig. 6).
IMPORTANT:
Please make sure that the leaves stop against the mechanical
stoppers inside the operator before they reached the
ground mechanical stopper. In not adjusted, unblocking will
be impossible.