Global 653558 Instrucciones De Ensamblaje página 8

Ocultar thumbs Ver también para 653558:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WIRING INSTRUCTIONS
For Model 653560
For Models 653558, 653670 & 653567
1. Open the compartment.
2. Connect the live wires to L1 and L2 of the
terminal block. Connect ground wire to
L1: White live wire L2: Black live wire
FOR 3 PHASE MODELS:
Models 653673, 653671, 653672, 653674, 653566, 653568,
Models 653561 653562 246067
653559 653561 653562 246067
653569 & 246068
1. Open the wiring cover.
2. Connect the red live wire to L1, black live wire
to L2 and white live wire to L3 of the connector.
Connect ground wire to
L1: Red live wire L2: Black live wire L3: White live wire
TROUBLESHOOTING
If your heater fails to operate, please follow these procedures:
This is a cart stand or wall-mounted heater. It has thermal
cut-off protection. If the thermal cut-off protection trips:
Turn off the power. Turn off the circuit breaker. The unit
Problem
Problem
Overheat protection has temporarily
Overheat protection has temporarily
deactivated the heater.
deactivated the heater.
Unit is not
Breaker/Fuse has been tripped.
Unit is not
heating.
heating.
Breaker/Fuse has been tripped.
Verify that there are no combustible
materials within 0.9 meters (3 feet)
surrounding the heater.
Verify that there are no combustible materials
within 0.9 meters (3 feet) surrounding the
There is oil residue on the heating coil
heater.
The heater is
from the manufacturing process. It will
The heater is
producing
There is oil residue on the heating coil from
evaporate quickly and should not occur
producing
a burning smell.
the manufacturing process. It will evaporate
again.
a burning smell.
quickly and should not occur again.
Ensure a minimum clearance of 4.5 inches
Ensure a minimum clearance of 4.5 inches
(11.5 cm) from heater to adjacent walls.
(11.5 cm) from heater to adjacent walls.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF.
DOING SO COULD CAUSE DAMAGE OR PERSONAL INJURY.
Salamander Heater
Electric Blower Heater
.
.
Probable Cause
Probable Cause
L2
L1
3. Close compartment.
Note: Use wire terminal crimp when connecting
to terminals.
L3
L1
L2
L1
L3
Ground wire
3. Close compartment.
should reset automatically after 10 minutes. If the thermal
cut-off protection trips again, consult a certified electrician
to determine the reason for overheating.
Solution
MODELS 653558, 653673, 653670, 653671,653672,
Turn the heater OFF; Switch off the circuit
653566, 653567, 653568 & 653569
breaker. Wait 10 minutes before restarting unit.
Turn the heater OFF; Switch off the circuit breaker.
Wait 10 minutes before restarting unit.
Check electrical box to confirm the breaker
MODELS 653674 & 246068
has not been blown. This may occur if the
Please refer to Page 7 Overheat & Reset.
receptacle is shared between other high
consumption appliances.
Check electrical box to confirm the breaker has not
been blown. This may occur if the receptacle is shared
Remove any combustible items near unit.
between other high consumption appliances.
Remove any combustible items near unit.
Ensure heater location is well ventilated.
Ensure heater location is well ventilated.
Reposition heater to increase distance from
Reposition heater to increase distance from
adjacent walls.
adjacent walls.
8
User's Manual
Solution
Tabla de contenido
loading

Tabla de contenido