TFA No. 30.5011 Anleitung 07/07
Operation:
Startup:
Remove the battery safety strip. Pull off the protection foil
on the display. The unit is now ready to use.
Display:
The left row shows the indoor relative humidity, the middle
row the room temperature and the right row the dew point.
The temperature unit can be changed from °C to °F by the
°C/°F-button at the backside.
Humidity alarm:
Select the humidity alarm value 65, 60 or 55 % by the sliding
switch at the backside.
If air humidity exceeds the selected value and there is a risk
of mould formation, the up-arrow and the red lamp will
flash and an alarm signal will sound for 1 minute. The alarm
can be turned off by pressing any button.
When air humidity falls below the selected value the up-
arrow and the red lamp will stop flashing. The up-arrow
remains on the LCD showing that humidity exceeded the
preset value at least once in the past. Press any button and
the up-arrow will disappear. The acoustic signal can be
muted by operating the sliding switch on the rear-side.
MIN / MAX temperatures:
• Press the MIN / MAX button and the highest temperature
and humidity is displayed since the last reset.
• Press the MIN / MAX button again, the display shows the
lowest temperature and humidity since the last reset.
• To go back to the present values, press the MIN / MAX but-
ton once more.
• Press the RESET button to reset the MIN / MAX values to
the present values.
Placing or hanging up the unit:
A circular opening is provided on the rear-side of the unit for
10
05.02.2009
9:02 Uhr
hanging on the wall. To place the unit in the standing posi-
tion use the foot supplied with the unit. Since the humidity
level within rooms can vary greatly according to the location,
mount the unit so that it will monitor the conditions in a
location likely to be subject to the most problems.
Battery replacement:
Remove the foot if necessary. Lightly push the silver battery lid
on the front down and open the battery compartment.
Replace the batteries (2 x 1.5 V AA). Do not use rechargeable
batteries. Attention: Please do not dispose of old electronic
devices and used batteries in household waste.
To protect the environment, take them to your retail store or
to nearest civic amenity site to be disposed of according to
national or local regulations.
Measuring range:
Relative humidity:
Tolerance
Temperature:
Tolerance:
SWISS PRECISION SENSOR
Our Swiss precision hygroTECH sensor
gives a particularly rapid and accurate
display of the air humidity.
Maintenance:
• Do not expose the instrument to extreme temperatures,
vibration or shock
• Clean it with a soft damp cloth. Do not use solvents or
scouring agents.
• Please do not try to repair the unit. Contact the original
point of purchase. Please change the batteries before
complaining. No guarantee if the instrument is handled or
opened improperly.
Seite 6
1% to 99 % r.F.
± 3.5% (30% to 75%)
-10°C to + 60°C
± 1%
11
loading

Este manual también es adecuado para:

30.5011