Tool changing.
Always secure the power tool
WARNING
with the supplied clamping
strap. In case of a power failure or when the
power plug is pulled, the magnetic holding
power is not maintained.
Switch the machine off and
WARNING
pull the power plug before
mounting or replacing application tools and
accessories (not overhead!). This preventive
safety measure rules out the danger of injuries
through accidental starting of the power tool.
Core drill bit (figure 6)
Loosen both screws of the tool holder using
the hex key.
Insert the pilot pin into the cutter.
Insert the cutter with the pilot pin into the
tool holder.
Tighten both screws of the tool holder onto
the flats on the cutting tool using the hex key.
When core drilling with 100 mm core bit
length, replace the 200 mm centering pin with
the 135 mm centering pin after a drilling
depth of approx. 60 mm.
Do not touch the sharp edges of the core drill
bit. Danger of injury.
Tap size (figure 6)
Loosen both screws of the tool holder using
the hex key.
Position the tap into the adapter and the
adapter into the chuck for the tap.
Tighten both screws of the tool holder onto
the flats on the cutting tool using the hex key.
Fig. 6
Clamping sleeve
6 mm
Centering pin
3.
Adapter
1.
Tap
Drill chuck for tap
2.
5.
1.
5.
1.
2.
3.
4.
Core drill bit
5.
3.
3.
5.
4.