IMPORTANT: If the pump fails to prime within five minutes:
7. Turn the power off at the breaker box. Check all pipe connections for leaks, making sure all
connections are water and air tight. Check the inlet pipe for any sagging, making sure the inlet pipe
is in a straight line to the pump. Watch for leaks or a milky color in the discharged water, which
indicates an air leak. Re-prime if necessary, following steps 1 through 6 above. Reset breaker at the
breaker box.
IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off
immediately. Check voltage. Pump is wired to run on 230 volts. If the pump cuts out or stops, you
may be attempting to connect to 115 volts. See PUMP ELECTRICAL INSTRUCTIONS to see how to
correctly change the motor voltage to 115 volts.
SPECIFICATIONS
HP
1-1/2
2
Item
HP
Number
1332-0006 1-1/2
1333-0006
MOTOR DATA CHART
Phase
Volts
Code Letter Max Amps
1
115
1
230
1
115
1
230
Capacity - U.S. Gallons per Minute
Discharge Pressure (PSI)
Vertical
Lift (FT)
15
10
66
15
62
20
54
25
40
10
67
15
63
2
20
59
25
37
18.0
G
9.0
21.0
G
10.5
PERFORMANCE
20
25
30
58
53
42
57
47
38
52
42
31
38
36
23
62
56
49
59
52
44
56
49
40
36
35
31
20
Locked Rotor
Amps
72.0
36.0
108.0
54.0
Inlet
Pipe
35
40
32
10
25
7
2 in.
13
3
12
0
39
27
34
25
2 in.
29
9
18
5
Outlet
Pipe
1-1/2 in.
1-1/2 in.