American Standard BEALE 4931380 Instrucciones De Instalación página 4

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6
CHECK CONNECTIONS FOR LEAKS
• Move HANDLE (1) into "off" position.
• Turn on water supplies and check connections for leaks.
• Operate HANDLE (2) up and down, left and right to flush
water lines thoroughly.
• Operate HAND SPRAY and check connections for leaks.
7
TEST INSTALLED FAUCET
•Turn ON water at main supply.
• With HANDLE (1) in "off" position, unthread SPRAY (3) from HOSE (2).
• Operate handle back to front, in COLD and HOT positions, to flush water
lines thoroughly.
• Replace SPRAY (3) onto HOSE (2).
• Please make sure that there is no cross threading.
7a
FAUCET OPERATION – AUTOMATIC MODE, MANUAL MODE AND FEATURES
Automatic Mode
• Make sure the SLIDING DOOR (1) and HANDLE (2) are in the open position.
• To turn on the water, momentarily place your hand within 3" of the
SENSOR (3).
• To turn off the water, momentarily place your hand again within 3" of the
SENSOR (3).
Manual Mode
• Close the SLIDING DOOR (1) and use the HANDLE (2) to turn on and off
the water.
FEATURES
Safety Timer
• The faucet will automatically turn off the water after 5 minutes of
continuous use. Momentarily place you hand in front of the sensor to
turn on the water.
Low Battery Indication
• The sensor will start to blink constantly every second. This is the indication
that the batteries are low in power. Replace the batteries with Qty. (4) AA
Alkaline type batteries.
• Battery lifetime is approximately 1 year under normal use.
CHECK CONNECTIONS
FOR LEAKS
CLOSED
- 4 -
3
REMOVE
OPEN
1
3
Closed
Cold
M965686 Rev. 1.9 (1/19)
1
Hot
Open
2
Tabla de contenido
loading

Este manual también es adecuado para:

Beale 4931385

Tabla de contenido