INsTallaTION INsTRUCTIONs (CONTINUED)
3. Remove nut which retains solenoid to coil and remove solenoid valve.
Observe the direction of flow indicator on the solenoid so that it can
be reassembled in the same direction.
4. Remove the stem assemble. Carefully unthread the stem assembly
of the solenoid (CCW). Do not strike or twist the stem with any object.
Doing so may damage the assembly.
5. Inspect valve seat and remove any foreign material.
6. Inspect plunger assembly and remove any foreign material. IF IT IS
NECESSARY TO USE A SOLVENT, IT MAY BE USED ONLY ON
METAL SURFACES.
7. Reassemble the solenoid and valve reversing the above procedures.
Be sure that the actuator cover is carefully aligned over the pin and
the additional outer cast portion is positioned on the outlet side of
the solenoid.
8. Reinstall solenoid into the housing, be sure the inlet and outlet are
positioned correctly for the flow.
Filter Ball Valve
and temperature ranges:
Max. Operation Pressure . . . . . . . . . . . . . . . 250 psig (17 Bar)*
Compressed Air Temp. . . . . . . . . . . . . . . . . . 33 to 265°F (0 to 130°C)
Ambient Temp. . . . . . . . . . . . . . . . . . . . . . . . 33 to 125°F (0 to 52°C)
(*) See "Specifications" for pressure rating, on page 5.
1. Open Strainer Ball Valve. (See Figure 4)
Figure 4
2. Set the "Time Off" and "Time On" knobs.
3.
During compressor operation, check for air leaks.
6
Do not operate the Condensate Drain
Valve outside the following pressure