INSTALLATION OF ACCESSORIES
9.1
Flue with raincover (fig. 4)
The heater is provided with a flue connection.
1. Fit a flue (B) to the flue connection (C).
Caution
The flue must point upwards. Never
place the flue pipe horizontal. An
angle of 45° is acceptable; minimum
length flue 1 m.
2. Fit a raincover (A) to the end of the flue.
9.2
Outlet hose
An outlet hose can be fitted to the outlet of
the heater, in order to blow heated air to a
remote space away from the heater.
Caution
Check the temperature resistance of
the used hose.
/i
Single
ITA 30/35
outlet
ITAS 30
Max.
L = 6 m:
∅300 mm
length
/i
Two way
ITA 30/35
outlet
ITAS 30
Max.
-
length
Please contact the dealer for information
about maximum lengths of outlet hoses,
bends, distribution pipes and hose clamps.
9.3
Room thermostat
See the instructions of the room thermostat.
9.4
Tank heating
See the instructions of the tank heating.