2 ON "Only open" radio control or pushbutton function enabled (with plug-in radio frequency card);
2 OFF "Open-close-reverse" radio control or pushbutton function enabled (with plug-in radio frequency card);
3 ON Enables 10-E output with moving and closing function;
3 OFF Enables 10-E output with moving function;
4 ON "Maintained action" function enabled;
5 ON Pre-flashing (aperture and closure) enabled;
6 ON Obstacle detection device (motor of limit position) enabled;
7 ON "slave" operation (motor is control in led externally) enabled;
8 OFF Immediate closure function enabled; activate safety device (2-C5).
9 OFF "stop" button enabled; activate safety device (1-2);
10 ON Function that increases the braking action on the barrier enabled.
Adjustments
Trimmer A.C.T. = Automatic closing time min. 1", max. 120".
Trimmer SENS. = Sensitivity of amperometric safety system (min./max.)
8
a
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.