You are in the main screen. Select "RH" and press the
PTK.
TMP = 33.6 °C
=> RH =
66%
BOX =
90%
CO2 = 1112 PPM
=> Humidity day Off
Hum. night
Off
Humidity +/- 5%
>> NEXT >>
Select "Humidity day" to set the desired level during the
day. Press the PTK to confirm.
If you want to completely disable air humidity regulation
during the day, set the value to "Off" again.
=> Humidity day 60%
Hum. night
Off
Humidity +/-
5%
>> NEXT >>
Select "Hum. night "and turn the PTK to set the desired
level. Confirm by pressing the PTK.
If you want to completely disable air humidity regulation
during the night, set to "Off".
Humidity day 60%
=> Hum. night
60%
Humidity +/-
5%
>> NEXT >>
11.1 Set hysteresis RH
The hysteresis is set to +/- 5% by default. To adjust the
setting, select "Humidity +/-" and turn the PTK. Confirm
by pressing the PTK.
Humidity day 60%
Hum. night
60%
=> Humidity +/-
3%
>> NEXT >>
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
11.2 Minimum/maximum RH level
Select >> NEXT >>.
Humidity day 60%
Hum. night
60%
Humidity +/-
3%
=> >> NEXT >>
Now you can read the minimum/maximum humidity
level.
To reset, select "Reset min/max" and press the PTK.
RH Min
49%
RH Max
54%
=> Reset min/max
>> NEXT >>
Select >> NEXT >> and press the PTK to return to the
main menu.
RH Min
49%
RH Max
54%
Reset min/max
=> >> NEXT >>
12. Measurement CO
The Clima Control displays the current CO
measured minimum/maximum CO
Sensor is connected. However, the Clima Control does
not control the CO
level.
2
TMP = 33.6 °C
RH =
66%
BOX =
90%
=> CO2 = 1112 PPM
The main screen displays the current CO
the next screen, select "CO2" and press the PTK.
CO2 Min
643PPM
CO2 Max
760PPM
=> Reset min/max
>> NEXT >>
level
2
level and the
2
levels, if a S-2 or S-4
2
level. To enter
2