Set the time between
changing the power
level of the box.
5s
Turn until the desired interval is reached (up to 250
seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a somewhat
longer interval.
If the temperature keeps fluctuating with the current
settings, you can change the interval.
If the temperature often increases too high, it is
recommended to shorten the interval. If the temperature
often falls too low, it is recommended to increase the
interval.
Confirm by pressing the PTK.
You enter the main screen.
TMP = 33.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
9.2 Standard menu
If you are not using the Custom menu (section 9.1),
select "Standard" and confirm by pressing the PTK.
Select box
Custom
=> Standard
Select the type of fan (m
Select fan
2500 m3
Push to confirm
By pressing the PTK, this fan is set as default. When
rebooting the Clima Control, these fan settings will be
used.
You enter the next screen:
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
) by turning the PTK.
3
Set the time between
changing the power
level of the box.
5s
Turn the PTK until the desired interval is reached (up to
250 seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a somewhat
longer interval.
If the temperature keeps fluctuating with the current
settings, you can change the interval.
If the temperature often increases too high, it is
recommended to shorten the interval. If the temperature
often falls too low, it is recommended to increase the
interval.
Confirm by pressing the PTK.
You enter the main screen.
9.3 Automatic or manual operation
You are in the main screen. Select "BOX" and press the
PTK.
TMP = 33.6 °C
RH =
66%
=> BOX =
90%
CO2 = 1112 PPM
Select "BOX A/M".
=> BOX A/M
Auto
BOX min
10%
BOX max
90%
Select box
In the "Auto" mode the fan will automatically run faster
if a measured value is too high. That is, if TMP is higher
than TMP setpoint + hysteresis. Every 5 seconds the fan
runs a little faster until the "BOX max" value is reached.
When the measured values return to normal, the fan
automatically runs slower until the set minimum capacity
(BOX min) is reached.
To set the minimum capacity of the box/fan, select "BOX
min".
20