Temp day
28.0°
=> Temp night 28.0°
Temp +/-
2.0°
>> NEXT >>
Select "Temp night" and press the PTK. Turn the PTK to
set the desired night temperature.
Press the PTK to confirm.
10.1 Set hysteresis
You are in the main screen.
Press the PTK once and select "TMP".
=> TMP = 30.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK.
Temp day
28.0°
Temp night 28.0°
=> Temp +/-
2.0°
>> NEXT >>
Select "Temp +/-" and press the PTK. Turn the PTK to set
the desired hysteresis.
Press the PTK to confirm.
10.2 Set Temp offset
Although the temperature sensor is very accurate, it may
be desirable to align it with other measuring equipment.
"Temp offset" allows you to adjust the indication with
+ or - 5.0 °C.
Select "Temp offset" in the TMP menu and press the
PTK.
=> Temp offset 0.0°
Night delay
5m
>> NEXT >>
Turn the PTK to select the desired degree of correction.
Press the PTK to confirm.
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
10.3 Set night delay
This function allows you to adjust the bridging time
between the moment that the light goes out and the
night temperature is valid. During this period the fan will
not start to run faster.
Select "Night delay" in the TMP menu and press the PTK.
Temp offset 0.0°
=> Night delay
5m
>> NEXT >>
Turn the PTK to select the desired time delay (up to 60
minutes).
Press the PTK to confirm.
10.4 Minimum/maximum temperature values
Select >> NEXT >> on the second page of the TMP
menu and press the PTK.
Temp offset 0.0°
Night delay
5m
=> >> NEXT >>
Now you can read the minimum/maximum temperature
values. To reset these values, select "Reset min/max" and
press the PTK.
TMP Min
26.2°C
TMP Max 33.6°C
Reset min/max
>> NEXT >>
Select >> NEXT >> and press the PTK to return to the
main screen.
11. Relative Humidity (RH) settings
If an RH sensor is connected to the Clima Control, you
can set the desired relative humidity level. By default the
RH values for day and night are off ("Humidity day" and
"Humidity night" are set to "Off"). You can adjust these
settings in the following way.
22