1.
ON/OFF switch.
2.
Continuous trigger action (4T).
3.
Normal/grid trigger action (2T).
4.
Digital panel.
5.
"Torch cutting" luminous indicator.
6.
Protection luminous indicator.
7.
Priming button.
8.
Reduce power (-).
9.
Increase power (+).
10.
Continuous/Discontinuous action selector button
of the torch (2T).
11.
Torch connector.
12.
Grounding clamp connector.
13.
PILOT ARC connector.
14.
Gun trigger connector.
15.
Plasma torch body.
16.
Trigger safety mechanism.
17.
Torch ON/OFF trigger.
18.
Power supply cable of the equipment.
19.
Fan/protection grid assembly.
20.
Pressure regulator/ air inlet filter and pressure reducer.
3.5 Limitations to environmental conditions.
The equipment shall be installed respecting its IP21 class, which
means that the equipment is protected at the most against
vertical impact of water drops and access to dangerous parts
with one finger against solid 12.5 mm ø or larger foreign bodies.
The equipment is prepared for working within a temperature
range from -15
C to 70
C, taking into account the limitation of a
o
o
decrease in performance (duty cycle) as of ambient temperatures
above 40
C.
o
►PUTTING INTO OPERATION P35.25C / PLASMA 25GE
1.
For installation in general, refer to illustrations 1 and 4.
2.
Fasten the grounding clamp to the material you will be
cutting.
3.
Connect to current supply.
4.
Press ON/OFF switch to start working.
► PUTTING INTO OPERATION P60.40B / PLASMA 40 GE
P60.80 / PLASMA 80 T GE - P60.120T / PLASMA120 T GE
1.
For installation in general, refer to illustrations 2-3 and 5.
2.
Position the air inlet coming from the machine's
compressor (4 to 6 bar). Rear portion.
3.
Fasten grounding clamp to the material you want to cut.
4.
Connect current supply cable.
5.
Connect red PILOT ARC cable.
6.
Connect thin black cable of the torch trigger.
7.
Connect torch (fig. 11).
8.
Press ON/OFF button to proceed to start the machine.
9.
The digital panel will light up (fig. 4).
10.
Check status of air (fig, 7) by pushing the torch switch. If
there is no air, the indicator (fog. 6) will turn on and the
digital panel will display code 806- Please revise the air
supply and confirm its good condition.
11.
Grip the torch (fig. 15) and press the yellow safety
pushbutton downwards (fig. 16) and immediately press
the switch on the torch (fig. 17) to proceed to cutting.
12.
Buttons 8-9 (+ -) are for increasing or reducing the power
of the torch. You must press to activate.
13.
Push button No. 10 for continued works.
14.
To work with 2T normal/ grid action of the trigger (fig. 3),
you must select button 10 and observe that led 3 lights up
(P60.40B/PLASMA40GE).
All manuals and user guides at all-guides.com
english
27
15.
16.
4. Operating instructions.
4.1. Positioning and testing.
All STAYER WELDING machines of the series must be handled
using the handle which is arranged for transport. A free space of
at least 15cm must be arranged around the equipment, and free
circulation of air must be ensured for correct heat dissipation.
Before each work, good operation and correct tightening of all
external elements of the equipment shall be verified: power
supply plug, cable, housing structure and connection terminals
and switches.
Model P35.25C / PLASMA 25 GE is a machine that is very
easy to use; after having verified the correct condition of the
above mentioned external elements, proceed to connect ground
connection (clamps as supplied), and then place the switch fig.
1 in its ON position to turn on; you will observe that the luminous
indicators figs. 2-3-4 light up. To turn off, only place the switch
fig. 1 in its OFF position.
►First step: INSTALLING THE COMPRESSED AIR.
The Plasma cutting equipments need air supply for working.
The Plasma shall be connected to a compressor capable
of providing about 5 bar constant pressure to the equipment.
Depending on the regularity of use, Plasma needs a larger or
smaller pressure vessels. Compressor of at least 2 horse powers
and 50 liters are recommended.
Install the regulator and additional filter in equipments which
carry them externally. Regulate air input pressure by turning the
upper control. To unlock the control, pull upwards gently. Check
the integrated flow meter if there is sufficient pressure (60 to 80
OSI, equivalent to 4-6 bar). The regulator has an internal safety
valve for cases of overpressure.
For regulating the air pressure, you must rotate regulator 20
(mod. P60.40B/PLASMA40GE) bearing in mind a maximum of
4 bar; you may increase or reduce the pressure by rotating it
sideward; after having finished, press inwards to secure.
27
To work with 4T continuous action of the trigger (fig. 2),
you must select button 10 and observe that led 2 lights up
(P60.40B/PLASMA40GE).
For continued works with model P60.40B/PLASMA40GE
you must select continued action 2 (4T) and action
normal/ grid 3 (2T) using button 10; both led must light up
at the same time.
EQUIPEMENT INCLUDED
MODEL
TORCH
P35.25C
Trafimet S25
see notice
PLASMA25GE
P60.40B
Trafimet S45
PLASMA40GE
P60.80
Trafimet S105
PLASMA80TGE
P60.120
Trafimet S105
/ Trafimet A141
PLASMA120TGE
Model P35.25C / PLASAM 25 GE does not need an
external compressor because it has its own one
installed within the equipment.
AIR REQUIREMENTS
COMPRESSOR
FLOW
PRESSURE
HP
(l/min)
(bar)
INTERNAL COMPRESSOR
115
5
2
180
5
2 / 3
180 /
5
3
210
Tabla de contenido