Connection
Connection
Venetian blind actuator 24V
(Fig. B): The bus line is connected at the bus connecting terminal (1).
The 24 V DC supply is connected to terminals + 1 / 2– (4). Outputs
A1 and A2 and motors M1 and M2 are at the same supplied with
power.
When outputs A3 and A4 are to be used, a 24 V DC supply must
additionally be connected to terminals + 3 / 4 –.
Important: Do not connect AC supplies to these terminals! The
B
polarity of the supplies connected to terminals + 1 / 2 – and + 3 / 4
– must be the same. There is otherwise a risk of irreparable damage
to the motors. Connection of motors to outputs A3 and A4 is
performed in the same way.
Legend: (2) hand controls and status indicators
(3) LED to indicate the switching state and the output
selected in manual operation.