Table 10-3
Information requirements for heat pump space heaters and heat pump combination heaters
Model(s):
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Declared climate condition:
Parameters are declared for low-temperature application.
Item
Rated heat output (*)
Declared capacity for heating for part load at outdoor
temperature Tj
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
Tj=bivalent temperature
Tj = operating limit
For air-to-water heat pumps:
Tj = -15℃
Bivalent temperature
Cycling
interval
capacity
forheating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Standby mode
Thermostat-off mode
Crankcase heater mode
Other items
Capacity control
Sound power level, outdoors
Annual energy consumption
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Annual electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,99.
V.2
32
Symbol
Value
Unit
Prated
20.8
KW
Pdh
18.47
KW
Pdh
10.26
KW
Pdh
6.69
KW
Pdh
6.63
KW
Pdh
18.47
KW
Pdh
21.18
KW
Pdh
-
KW
Tbiv
-7
Pcy ch
-
KW
Cdh
0.9
--
Pof f
0.075
kW
Psb
0.075
kW
Pto
0.5
kW
Pck
0.075
kW
variable
LWA
78
dB
QHE
13189
kWh
-
Qelec
-
kWh
AEC
-
kWh
ECH-030NVTBI
AVERAGE
Item
Seasonal space heating energy efficiency
Declared coefficient of performance or primary energy ratio for part load at
outdoor temperature Tj
Tj = -7℃
Tj = 2℃
Tj = 7℃
Tj = 12℃
Tj=bivalent temperature
Tj = operating limit
For air-to-water heat pumps: Tj = -15℃
For air-to-water heat pumps: Operation limit
temperature
Cycling interval efficiency
Heating water operating limit temperature
Supplementary heater
Rated heat output (**)
Type of energy input
For air-to-water heat pumps: Rated air flow
rate, outdoors
For water- or brine-to-water heat pumps: Rated
brine
or
water
flow
rate,
heatexchanger
Water heating energy fficiency
Daily fuel consumption
Annual fuel consumption
YES
NO
NO
YES
NO
NO
Symbol
Value
ηs
128
COPd
2.56
COPd
3.64
COPd
4.73
COPd
6.04
COPd
2.56
COPd
2.25
COPd
-
TOL
-10
COPcy c
-
WTOL
-
Psup
-
-
-
12500
outdoor
-
-
ηwh
-
Qf uel
-
AFC
-
Unit
%
-
-
-
-
-
-
-
-
-
㎥/h
㎥/h
%
kWh
GJ