5.8 READING SETTINGS ON THE DISPLAY
12:12 SUNDAY
-05-
Information on how the softener is working and what it is
going to do is viewed on the display.
Two lines are used to view the different messages. The top
line shows current day and time; the bottom line shows the
softener model and the program it is running.
Display version when the softener is set on weekly chro-
nometric mode (paragraph 5.2.1)
12:12 SUNDAY
-05- -07 RIG F10
In the top line current time and day are visible; in the bot-
tom line the model -05- (AL5) and some figures are viewed
(3.7). They stand for the days of the week in which regenera-
tion cycles will take place 1 stands for Monday, 2 stands for
Tuesday, 3 stands for Wednesday, and so on and so forth...
3.7 means that regenerations will take place on Wednesdays
and on Sundays, that is to say on the third and seventh day
of the week.
Display version when the softener is set on chronometric
mode and shows days interval (paragraph 5.2.2)
Two lines are used to view the different messages. The top
line shows current day and time; the bottom line shows the
softener model (-05-) AL5, and how many days are to elapse
before next regeneration. -07REG = 7 is regeneration fre-
quency; in thix case, F10 means that the softener is set so as
to carry out a regeneration cycle every 10 days.
CAUTION: if F00 appears on the display, the softener will
never carry out automatic regeneration; regeneration will only
take place in semi-automatic mode (paragraph 7.1).
Display version when the softener is set in volumetric
mode (paragraph 5.7.1)
12:12 SUNDAY
-05-V (R)
In the top line current time and day are visible; in the bottom
line the model (-05-) and
letter V – for volumetric – are displayed.
5.8.1 READING INSTRUCTIONS ON THE DISPLAY
Irrespective of the actual softener setting, some other fun-
ctions will appear on the display. After the name of the day,
one, two or no star symbol can be viewed.
12:12 SUNDAY
*
+05+V
R
When no star symbol is visible on the display, salt control is
on. Thanks to this setting, in case of salt shortage, a visual
message will be displayed (red led lights on and the "ADD
SALT" / "CHECK SALT" message) just as an audible alarm
will be on.
- One single star symbol means that salt control is on, but
Instruction Manual AL VOLUMETRIC
VOLUMETRIC
3
7
•
**
*
it will only be visually signaled by red led lights on and the
"ADD SALT" / "CHECK SALT" wording on the display.
- Two star symbols mean that salt control is off and that,
once salt is over, no signal will be visible.
When *R* and (R) are displayed, the softener will carry out the
regeneration cycle on the preset day and time.
When "+08+" is displayed before and after the model type,
the regeneration times with extra-rinse have been changed
(see paragraph 5.5).
5.8.2 READING OF SETTINGS AND ALARMS
When the softener is in service, by pressing
ner operation and setting data can be viewed.
Softener in chronometric mode on a weekly regenera-
tion program
+
regeneration starting time is displayed
+ +
week days with "*" mean that, on those
days, regeneration will take palce
+ + +
past alarm log
+ + + +
first installation
+ + + + +
salt warning
Softener in chronometric mode on a regeneration pro-
gram based on the number of days elapsing between
cycles.
+
regeneration starting time is displayed
+ +
past alarm log
+ + +
first installation
Softener in volumetric mode.
+
+ +
+ + +
+ + + +
+ + + + +
+ + + + + +
+ + + + + + +
+ + + + + + + +
As to "PAST ALARM LOG" and "FIRST INSTALLATION",
When "PAST ALARM LOG" is displayed, all the alarms recor-
ded by the softener are viewed by pressing the
Alarms are recorded by the softener according to a numerical
order that also provides date and time information.
There are three types of alarm: AS is displayed in case of
salt shortage; CS: Signals to check the salt, E1 and E2 are
displayed in case of system errors.
Caution: if salt shortage control is put in the off position, the
softener will not record such event in the log (paragraph 5.6).
When FIRST INSTALLATION is displayed, the softener shows
the date on which the third automatic regeneration was carri-
ed out. It can be treated as the true start of the device.
ENGLISH
+
some softe-
regeneration starting time is di-
splayed
remaining operating range, how
much softened water can still be
supplied
water hardness
the number of days during which
forced regeneration will be carri-
ed out
softened water average consu-
mption per day
past alarm log
first installation
salt warning
they are the same for the three
programs.
–
key.