Ibx S50L Manual De Usuario página 8

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

compressor
uP-
Start threshold
Compressor
dn-
Closing the
threshold
Floodlight
Lt-
time
Sterilization lamp
St-
time
Pb-
Zero adjustment
Full degree
adjustment
PK-
INDICATOR
NAME
Lc
Password
Power down
rES
memory function
FAn
Fan Type selection
Maximum power
nP-
output
When the compressor is working intermittently, IF
temperature
temperature
measurement
set value
AND the compressor start delay time is up, THEN
the compressor starts working.
Note: This parameter is valid only in the manual
start/stop mode.
When the compressor is working in the
intermittent mode, IF
temperature
temperature
measurement
THEN, the compressor turns OFF.
Note: This parameter is valid only in the manual
start/stop mode.
Time the floodlight stays ON every time.
When Lt=0, the delay is invalid and the lights
need to be turned off manually.
Time the sterilization lamp stays ON every time.
When St=0, the delay is invalid and the lights
need to be turned off manually.
Correction of errors caused by sensor low
temperature measurement.
actual
Pb
=
temperature
value
Correction of errors caused by sensor high
temperature values.
actual temperature
value
×
=
1000
PK
temperature measured value
FUNCTION DESCRIPTION
The password to modify the parameters in this
table is Lc = 9
0: OFF – if the power goes off, the controller
will stop working.
1: ON – if the power goes off, when the device
is turned on again it will continue running the
functions it was running when the power went
off.
0: The fan is a short axis fan.
1: Fan is a long shaft fan.
The maximum power percentage of the heating
output.
+
uP
+
dn
set value
temperature
_
measured
value
temperature
-
measured value
8
(-10.0~10.0℃)
0.4
(-10.0~(uP-0.1))
0.2
(0~9999min)
0
(0~9999min)
0
(-99.9~99.9℃)
0
(-999~999) 0
FACTORY VALUE
0
(0~1)
0
(0~1)
0
(0~100%)
100