INDICATOR
NAME
Lc-
Password
EAr
Gear ratio
Motor pole
PoL
number
Motor rotation
dIF
Reference
direction
Speed
FdS
feedback
value
Current
FdC
feedback
value
Carrier
FrE
frequency
Po-
Motor power
Overflow
CL-
multiple
Rotation
direction
Fr-
selection of
motor
Insensitive
db-
display
area
False display
dF-
interval point
FUNCTION DESCRIPTION
The password to modify the parameters in this
table is Lc = 9
big gear diameter
EAr
=
pinion diameter
DC brushless motor pole pairs.
0: clockwise rotation
1: counterclockwise rotation
Speed feedback coefficient value
Current feedback system value
Brushless motor carrier frequency
Note: when the carrier frequency is changed,
the controller needs to be restarted.
Brushless motor power.
Note: this parameter must be adjusted
according to the actual power of the motor.
Allowable current multiplier for overcurrent
protection of motor.
0: The motor only runs in forward rotation.
1: The motor only runs in reverse.
2: The motor can run in both directions.
Speed display insensitive area
IF
speed set value
dF
≥
THEN both the speed set value and the speed
display value are false display values.
11
FACTORY VALUE
0
(1.0~10.0)
3.2
(1~32)
4
(0~1)
0
(0.1~10.0)
1.0
(0.1~10.0)
1.0
(5~15)
15
(1~400)
Low voltage driver: 80
High voltage driver: 200
(1.0~10.0)
5.0
(0~2)
0
(0~100)
2