INDICATOR
NAME
Lc-
Password
EAr
Gear ratio
Motor pole
PoL
number
Motor rotation
dIF
Reference
direction
Speed
FdS
feedback
value
Current
FdC
feedback
value
Carrier
FrE
frequency
Po-
Motor power
Overflow
CL-
multiple
Rotation
direction
Fr-
selection of
motor
Insensitive
db-
display
area
False display
dF-
interval point
FUNCTION DESCRIPTION
The password to modify the parameters in this
table is Lc = 9
big gear diameter
EAr
=
pinion diameter
DC brushless motor pole pairs.
0: clockwise rotation
1: counterclockwise rotation
Speed feedback coefficient value
Current feedback system value
Brushless motor carrier frequency
Note: when the carrier frequency is changed,
the controller needs to be restarted.
Brushless motor power.
Note: this parameter must be adjusted
according to the actual power of the motor.
Allowable current multiplier for overcurrent
protection of motor.
0: The motor only runs in forward rotation.
1: The motor only runs in reverse.
2: The motor can run in both directions.
Speed display insensitive area
IF
speed set value
dF
THEN both the speed set value and the speed
display value are false display values.
11
FACTORY VALUE
0
(1.0~10.0)
3.2
(1~32)
4
(0~1)
0
(0.1~10.0)
1.0
(0.1~10.0)
1.0
(5~15)
15
(1~400)
Low voltage driver: 80
High voltage driver: 200
(1.0~10.0)
5.0
(0~2)
0
(0~100)
2