Main Switch; Control Unit - RedMax BTR250PL Manual De Taller

Ocultar thumbs Ver también para BTR250PL:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7. Assemble the trimmer guard. See
trimmer guard on page 13

5.11 Main switch

5.11.1 To disassemble the main switch
CAUTION: Do not pull on the wires. Hold the
contact only when you pull it out.
1. Dismantle the operating handle. See
disassemble the operating handle on page 14
2. Dismantle the power trigger lock and power trigger.
To disassemble the power trigger lock and
See
power trigger on page 14
3. Lift out the main switch and disconnect cable (A).
4. To disconnect the cable (A), free the catch (D) with a
small screwdriver and pull the contact (C) out.
C
572 - 001 - 28.03.2018
To assemble the
To
A
D
5.11.2 To assemble the main switch
1. Connect cable (A) and make sure that the contact
clicks into place. Place the main switch in the battery
housing.
2. Assemble the power trigger lock and power trigger.
To disassemble the power trigger lock and
See
power trigger on page 14
3. Assemble the operating handle. See
the operating handle on page 14

5.12 Control unit

5.12.1 To disassemble the control unit
1. Dismantle the handle and the operating handle. See
To disassemble the operating handle on page 14
2. Dismantle the wear guard under the battery housing.
To disassemble and assemble the battery
See
housing wear guard on page 13
3. Dismantle the battery housing. See
the battery housing on page 14
4. Loosen the screws (G) to the control unit and the
screws (H) to the battery contact and lift out the
entire unit and the fan.
A
To assemble
To disassemble
G
H
H
Repair instructions - 11
G
Tabla de contenido