English
•
An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The smaller
the gauge number of the wire, the greater the capacity
of the cable, that is, 16 gauge has more capacity than 18
gauge. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. When using
more than one extension to make up the total length,
be sure each individual extension contains at least the
minimum wire size. The following table shows the correct
size to use depending on cord length and nameplate
ampere rating. If in doubt, use the next heavier gauge. The
lower the gauge number, the heavier the cord.
Minimum gauge for Cord sets
Total length of Cord in Feet
Volts
120 V
25 (7.6)
240 V
50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
Ampere Rating
More
not
American Wire gauge
Than
More
Than
0
6
18
6
10
18
10
12
16
12
16
14
The label on your tool may include the following symbols. The
symbols and their definitions are as follows:
V ......................... volts
Hz ....................... hertz
min ..................... minutes
or DC ...... direct current
...................... Class I Construction
(grounded)
.../min .............. per minute
BPM .................... beats per minute
IPM ..................... impacts per minute
RPM .................... revolutions per
minute
sfpm ................... surface feet per
minute
SPM .................... strokes per minute
OPM .................... oscillations per
minute
A ......................... amperes
W ........................ watts
or AC ........... alternating current
or AC/DC .... alternating or
direct current
...................... Class II
Construction
(double insulated)
n o ....................... no load speed
n ......................... rated speed
...................... earthing terminal
..................... safety alert symbol
4
(meters)
50 (15.2) 100 (30.5) 150 (45.7)
16
16
14
16
14
12
16
14
12
12
Not Recommended
..................... visible radiation
..................... avoid staring at
light
..................... wear respiratory
protection
..................... wear eye
protection
..................... wear hearing
protection
..................... read all
documentation
../min or ..min
. Revolutions or
-1
Reciprocations per
minute
2
.................. two phase
alternating current
2N
............... two phase
alternating current
with neutral
3
.................. three phase
alternating current
3N
............... three phase
alternating current
with neutral
.................. rated current of the
x
appropriate fuse-
link in amperes
............ time-log miniature
A
fuse-link where X
is the symbol for
the time/current
characteristic, as
SAVE THESE INSTRUCTIONS FOR
FUTURE USE
COMPONENTS (FIG. A)
Motor
Be sure your power supply agrees with the nameplate
marking. Voltage decrease of more than 10% will cause loss
of power and overheating. These tools are factory tested; if
this tool does not operate, check power supply.
Intended Use
This reciprocating saw is designed for professional use.
DO nOT use under wet conditions or in presence of
flammable liquids or gases.
DO nOT let children come into contact with the tool.
Supervision is required when inexperienced operators use
this tool.
ASSEMBLY AND ADJUSTMENTS
WARNING: To reduce the risk of serious personal
injury, turn unit off and disconnect it from
power source before making any adjustments or
removing/installing attachments or accessories.
An accidental start-up can cause injury.
WARNING: Cut hazard. Blade breakage may occur
if the blade does not extend past the shoe and the
thickness of the workpiece during the cut. Increased
risk of personal injury, as well as damage to the shoe
and workpiece may result.
Blade Installation and Removal (Fig. B)
To Install a Blade
1. Point tool away from body.
2. Use the tab on the blade clamp collar
the collar to its full open position.
3. Insert blade
fully into blade clamp collar.
7
nOTE: Blade can be installed with the teeth facing up to
assist in Flush Cutting.
4. Release blade clamp collar and gently tug on the blade to
ensure blade is clamped securely.
Fig. B
given in
IEC 60127-3
IPXX .................... IP symbol
6
, rotate open
7
6