General Information; Power Requirements; Dimensional Data; Safety Information - Pentair HYPRO PROSTOP-E Manual De Instalación Y Funcionamiento

Ocultar thumbs Ver también para HYPRO PROSTOP-E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
INSTALLATION & OPERATION

GENERAL INFORMATION

Prostop-E valves provide precision control of on/off function of
spraying with high flow and low power consumption.
PERFORMANCE
Operating Pressure..............150 PSI (10 bar) max
Flow.....................................2.0 GPM with 5 PSI pressure
drop through valve (7.57 LPM @ 0.34 bar)
Wetted Components.............FKM, Nylon, Viton, Stainless
Steel, Acetal, Teflon

POWER REQUIREMENTS

Voltage...............................9 to 16 VDC
Steady State Amperage......................50 mA
Actuating.......................... 1.9 A in-rush current (50
milliseconds), 550 mA for a total time of 250 ms

DIMENSIONAL DATA

L-3111 (04-15-21)
3
Tabla de contenido
loading

Tabla de contenido