9 - RESET PROCEDURE

Reset procedure deletes door travel parameters (par. 6) and all
advanced functions (par. 11). It can be performed in case of
programming mistakes and it brings the control board to factory
settings.
m
This reset doesn't affect memorized radio transmitters
(see par. 5 for radio trasmitters management).
1. PRESS THE START BUTTON FOR 8 SECOND: All LED flash
2. RELEASE START BUTTON: All LED continue to flash
3. PRESS THE START BUTTON FOR 3 SECOND: All LED light up in
series
4. RESET IS NOW COMPLETED: The red "ERROR" LED lights
flashes 3 times continuosly
5. A NEW PROGRAMMING OF THE AUTOMATION'S
MOVEMENTS IS REQUIRED
10 - DEVICES CONNECTABLE TO THE
CONTROL UNIT
The control unit is prearranged for interfacing with different
devices dedicated to system control, system safety and other
additional functions. Below is a list of their connections and
corresponding functions.

10.1 - LAMPEGGIANTE

TERMINALS: 1-2
The warning light is an accessory used for signaling any
movement of the gate leaf.
Connected lamps: 24V 15W maximum power.

10.2 - AUX CONTACT

TERMINALS: 11-12.
Default setting: 12V electric lock operation.
The AUX can be set to electric lock, magnetic lock, courtesy light
(monostable or bistable). Also, voltage output is customizable to
24V.
To change the AUX setup, refer to the advanced programming
functions of Paragraph 13:
-
Selection of AUX output type (Paragraph 13.1) = set as lock or
courtesy light;
-
Selection of AUX operating mode (Paragraph 13.2) = allows
for customizing the contact's operation;
-
Selection of AUX contact voltage (Paragraph 13.3) = allows for
selecting the AUX contact voltage (12V or 24V).

10.3 - SAFETY DEVICES

TERMINALS: 4-9-10.
Control unit has two safety inputs available for voltage free (dry
contact) connection(s).
10.4 - "S2 PHOTO" CLOSING OR OPENING/
CLOSING PHASE SAFETY DEVICES
TERMINALS 4-8
Allow connection of safety devices active during closing and
opening phase. This input is normally closed (NC).
For infra-red photocells and safety edges with micro-switch
contact.
The factory wire bridge connected to S2 Photo must be removed
when using this input.
m
When multiple devices are connected on this contact,
they must be series connected.
10.5 - "S1 EDGE" OPENING/CLOSING PHASE
SAFETY DEVICES
TERMINALS 9-10
It is possible to connect devices (e.g. photocells or edges) with
normally closed (NC) contact or 8K2 resistive edges to the "S1
Edge" input.
The factory wire bridge connected to PHO2 must be removed
when using this input.
These devices intervene while the door is moving, in particular:
-
with the closed door they lock opening commands.
-
with the opened door they lock closing commands.
-
during the closing phase they command a brief inversion
-
during the opening phase they block the movement