The heater is primarily for outdoor use only (see diagrammatical
representations of outdoor areas). Do not use it for indoors or in an enclosed
area. Always ensure that adequate fresh air ventilation is provided.
•
Do not use the heater for the heating of domestic premises.
•
Do not use the heater in the basements or below ground level.
•
This appliance shall only be used in an above ground open-air situation with
natural ventilation, without stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind and natural convection.
•
Any enclosure in which the appliance is used shall comply with one of the
following:
-
An enclosure with walls on all sides, but at least one permanent opening at
ground level and no overhead cover.
-
Within a partial enclosure that includes an over head cover and no more
than two walls.
-
Within a partial enclosure that includes an overhead cover and more than
two walls, the following shall apply:
--- At least 25% of the total wall area is completely open, and
--- At least 30% of the remaining wall area is open and unrestricted.
--- In the case of balconies, at least 20% of the total wall area shall be and
remain open and unrestricted.
•
This appliance shall be used only in an outdoor area and shall not be used in a
building, garage or any other enclosed area.
•
Always maintain 1.2-m (47") clearance from combustible materials from the
top and side.
•
Heater must be placed on level firm ground.
•
Never operate heater in an explosive atmosphere like in areas where gasoline
or other flammable liquids or vapors are stored.
•
To protect heater from strong wind, anchor the base securely to the ground
with screws.
HEATER LOCATION
120 cm