INSTALLATION REQUIREMENTS
To avoid installation difficulties, read instructions
completely before starting. This publication contains
important information for the installation and
operation of your room air conditioner. Your air
conditioner will install into standard double hung
windows with actual clear opening widths of 26 to
39-3/8 inches (660mm to lOOOmm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 12 inches (305ram). However,
some window frame design variations require
modification to the window for safe, proper
installation. Side louvers and the roar of the air
conditioner must have clear air space to allow
enough airflow through the condenser for heat
removal. The rear of the unit must be outdoors, not
inside a building or garage.
F-Sash
_I_26'(S60mm)
to _
393/8'(10(_(}mm)
12'(30_m} m_r_.
F
Window
Inner si!/ _
_
Offset
._':'
Exterior
o"'
FIG. 1
ELECTRICAL
SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (found on left side of front
grille).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your ptug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton is the best way to store
unit during winter or when not in use.
INSTALLATION
HARDWARE
ITEM
NAME OF PARTS
Q'TY
A
SUPPORT, BRACKET
1
B
LEVELING BOLT
1
C
LEVELING BOLT
1
D
SCREW: 5/8"
2
E
SCREW: 5/8"
5
F
FOAM SEAL
1
G
FOAM STRIP
1
H
L BRACKET
1
REQUIRED TOOLS:
• Tight Fitting gloves
• Standard screwdriver
• Phillips screwdriver
• Pencil
• Sharp knife
• Tape measure
• Electric drill
• 1/4-inch drill bit
To avoid riskof personal injury, property damage,
or product damage due to the weightof this
device and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• Carefully inspect location where air conditioner
willbe installed. B e sure itwillsupportthe
weight of the unit over an extended period of
time.
• Handle air conditioner with care.
Wear protective gloves whenever lifting or
carrying the unit. AVOID the sharp metal fins of
front and rear coils.
• Make sure air conditioner does not fall during
installation.
FIG. 2
-5-