INSTALLATION REQUIREMENTS
Your air conditioner will install into standard double
hung windows with actual clear opening widths of
22 to 36 inches (559mm to 915mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 15 inches (381mm). Side louvers
and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
22"_O36"
I 1 is
.,in
innersillL
|
Window
II
O,set
Interior wall "',J
o[,"
FIG. 1
ELECTRICAL
SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (found on rightside of cabinet),
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton is the best way to store
unit during winter or when not in use.
INSTALLATION
HARDWARE
ITEM
A
B
C
D
E
F
FIG. 2
i
f
I
REQUIRED TOOLS:
NAME OF PARTS
SIDE CURTAIN
SILL SUPPORT
BOLT
LOCK NUT
SCREW: 25/64"
SCREW: 5/8"
SCREW: 5/8"
FOAM SEAL
FOAM STRIP
L BRACKET
Q'TY
2
2
2
2
13
3
5
1
1
1
To avoidrisk of personal injury,property damage,
or product damage due to the weightof this
device and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspect location where air conditioner
will be installed. Be sure it will support the
weight of the unit over an extended period of
time.
i Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
Make sure air conditioner does not fall during
installation.
• Tight Fitting gloves
• Standard screwdriver
• Phillips screwdriver
• Pliers
• Sharp knife
• 3/8-inch open end wrench or adjustable wrench
• 1/4-inch hex socket and ratcher
• Tape measure
Electric drill
1/4-inch drill bit
-5-