WARNING
Improper installation of the grounding
circuit can result in a risk of electric shock.
Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, if
doubt exists as whether the appliance is properly
grounded.
CAUTION
For European style cabinets (flush front) the required
clearance for operation of the oven door is minimum
spacing of 7/8² between the cutout and the door, hinge
or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due to
their construction, to allow this installation.
Installation
1. Cut hole in cabinet to mount oven. Cutout in cabinet
should be level and straight.
NOTE: There are no provisions to level the unit after it
is installed. An oven that is not level could cause poor
baking results.
2. Install plywood floor as shown.
3. Remove oven door(s). See Oven Door Removal
procedure.
4. Attach unit to the cabinet with four No. 8 x 1² screws
supplied with unit inside of envelope containing these
instructions. Pre-drill holes in cabinet for attachment
screws using 1/8² drill. Oven mounting holes are
provided in side trim.
5. Install bottom trim.
6. Replace oven door(s). See Oven Door Replacement
procedure.
7. See instructions at right for electrical hook-up.
8. See Use and Care Manual for operating instructions.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE
Installing Bottom Trim Piece
Remove lower screws from hinge
receptacle plates. Align lower trim
and reinstall screws.
DO NOT INSTALL BOTTOM TRIM UNTIL UNIT IS
ATTACHED TO THE CABINET.

Electrical Connections

Unit to be properly circuit protected and wired according
to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
front of unit for power requirements.
The neutral of this unit is grounded to the frame through
the solid grounding wire. (The ground and the white wires
are twisted together at the termination of the conduit.) If
used on new branch-circuit installations (1996 NEC),
mobile homes, recreational vehicles, or in an area where
local codes prohibit grounding through the neutral
conductor, untwist or disconnect the ground wire and
connect to ground in accordance with local code. Connect
the white neutral to the service neutral. Connect all wires
to the branch circuit with approved connectors. Use
copper or aluminum wire. If aluminum wire is used, use
connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit on
the circuit.
RECOMMENDED MINIMUM
K.W. RATING
ON SERIAL PLATE
0 - - 4.8
4.9 - - 6.9
7.0 - - 9.9
10.0 - - 11.9
12.0 - - 14.9
Service
Interrupt the source of electricity to the unit when
attempting to repair or service the oven. Failure to do this
could result in a dangerous or even fatal shock.
3
WIRE SIZE
CIRCUIT PROTECTION
IN AMPERS
20
30
40
50
60
(AWG)
12
10
8
8
6