Mini lnfraRed Thermometer/English
SAFETY
• Use extreme caution when the laser beam is turned on.
• Don't look at laser. Don't point laser directly at persons or
animals.
• Be careful not to let the beam point at reflective surface
that may strike your eye.
• Don't use around explosive gas or vapor.
Distance & Spot size
As the distance (D) from the object increases, the spot size
(S) of the area measured by the unit becomes larger. The
relationship between distance and spot size for each unit is
listed below. The focal point for each unit is 914mm (36").
The spot sizes indicate 90% encircled energy.
D:S=12:1
12.5mm @ 150mm
2
25mm @ 300mm
0.5in @ 6in
1in @ 12in
D
13/05/2017 Version No. 001
3.Specifications
Temperature range
-50 to 380°C(-58~716°F)
Display resolution
Accuracy
-50~20°C(-58~68°F)
20~380°C(68~716°F)
Repeatability
Response time
Spectral response
Over range indication
Diode laser
Operating temp.
Storage temp.
Relative humidity
Power supply
Note:
Field of View: Make sure that the target is larger than the unit's spot
size. The smaller the target, the closer you should be to it. When
accuracy is critical, make sure the target is at least twice as large as
the spot size.
S
13/05/2017 Version No. 001
Mini lnfraRed Thermometer/English
D:S
12:1
0.1°C(0.1°F)
For targets:
±2.5°C(4.5°F)
±1.0% ±1°C(1.8°F)
±1°C(1.8°F)
150ms
8~14um
LCD will show "----"
output <1mW,Wavelength 630~
670nm, Class 2 laser product
0 to 50°C(32 to 122°F)
–10 to 60°C(14 to 140°F)
10%~90%RH operating,
<80%RH storage
9V Battery, NEDA 1604A or
IEC 6LR61, or equivalent
3