Maintenance; Routine Maintenance; General; Lubrication - CAMPAGNOLA OLISTAR METAL TOP Manual De Uso Y Mantenimento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
6

- MAINTENANCE

6.1 Routine maintenance

WARNING!
Before carrying out any maintenance operation, disconnect the tool from the compressed air hose.
All the maintenance operations which are not described in this manual have to be performed in a CAMPAGNOLA
S.r.l. Authorized Service Point.
The ordinary maintenance operations may be carried out by the operators.

6.1.1 General

Before any maintenance operations:
Engage the safety catch (23).
Disconnect the compressed air hose.

6.1.2 Lubrication

Every 20 working hours use an oiler to add some oil drops through the air fi tting (26). Use Campagnola BIG FLU or low
toxic FUDY FLU.
Lubricate the link (6) of the rake (2) with spray grease.
Periodically check the oil level in the lubricator of the compressor (see the note in par. 4.2).
WARNING!
Do not use hydraulic oil or oil for braking systems. They may cause irreversible damages.

6.1.3 Cleaning and putting the tool away

At the end of work, it is good practice to pour some diesel fuel drops through the air fi tting (26), located on the handle,
before putting the harvester away. To do this, make the tool idle for few seconds.
This will prevent dirt and moist air from forming build-ups.
WARNING!
Do not throw the oil out in the environment. Always observe current environmental protection laws when disposing of
the oil.
22 - 68
Tabla de contenido
loading

Este manual también es adecuado para:

Olistar tuono

Tabla de contenido