4. THIS DEVICE DOES NOT DETECT FLAMES, HEAT, CARBON MONOXIDE OR OTHER HAZARDOUS GASES.
WARNING!
1. NEVER IGNORE ANY ALARM. FAILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH.
2. THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM. ALWAYS CHECK
YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM. FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH.
3. TEST THIS SMOKE ALARM ONCE A WEEK. IF THE ALARM EVER FAILS TO TEST CORRECTLY, REPLACE IT IMMEDIATELY!
IF THE ALARM CANNOT WORK PROPERLY, IT WILL NOT ALERT YOU TO A PROBLEM.
Set up and Interconnect Smoke Alarms
All XS01-WR alarms contain a built-in RF module that enables you to wirelessly connect 2 or more smoke alarms and
create an interlinked network. When one unit is triggered, all interconnected units will sound an alarm.
The XS01-WR wireless smoke alarms in one multi-pack have already been interconnected. The alarms in
each multi-pack have their own independent interlinked network. So, if you have more than one
multi-pack, you will need to add them all into the same interlinked network.
H ow to Interconnect
1. To power on 2 smoke alarms, remove the battery insulating fi lms from their battery compartments.
Note: Make sure that only 2 smoke alarms are powered on at a time to ensure successful interconnection.
2. Press the test/silence button on one of the 2 smoke alarms 4 times, and this alarm will beep once and the red LED
will fl ash continuously, indicating it has entered the interconnecting mode. After successfully creating an interlinked
network, this alarm will beep once and automatically exit the interconnecting mode. To ensure that all smoke alarms
02
enter the same interlinked network, make sure only one smoke alarm enters interconnecting mode at a time.
3. If you want to interconnect a third smoke alarm, power it on and press the test/silence button 4 times to
interconnect to the previously interconnected smoke alarms. Up to 24 smoke alarms can be interconnected
this way.
4. Test the smoke alarm according to the steps in the section "Alarm Test".
Press
4 times
Press
4 times
Hold
down
03