Restoring Using the WebUI

Use the WebUI of the applicable operating system to restore the appliance to the
factory default settings. You can select one of the software images that are available
on the appliance.

Gaia

Use the Gaia WebUI to restore the default factory settings.
To restore a Gaia appliance with the WebUI:
1. Open an Internet browser to the management IP address,
https://<appliance_ip_address>
2. Log in to the WebUI of the appliance using the administrator username and
password.
3. In the WebUI, click Maintenance > Factory Defaults.
The Factory Defaults window opens.
4. Select the image version that you are restoring.
5. Click Apply.

SecurePlatform

Use the SecurePlatform WebUI to restore the default factory settings.
To restore a SecurePlatform appliance with the WebUI:
1. Open Internet Explorer and navigate to the management IP address,
https://<appliance_ip_address>:4434
2. Log in to the WebUI of the appliance using the administrator username and
password.
3. In the WebUI, click Appliance > Image Management.
The Image Management window opens.
4. Select the image version that you are restoring.
5. Click Revert.