Production code filter cartridge – example: B9224350010
9
Production year, this example:2019
22
Production week, this example: calendar week 22
4
Production day from Monday(1) to Friday (2), this example: Thursday
35
Internal Identification No. of filter medium this example: No. 35
0010
Consecutive number of the filter cartridge, this example the tenth cartridge; reset the day changes
3.5 Technical Safety Assembly Instructions
•
The appliance in which the filter is used must be free of limescale and gypsum deposits prior
to installation.
•
Protect the filter system from sunlight and mechanical damage. Do not assemble near sour-
ces of heat and open flames.
•
A stop valve must be installed before the filter system inlet hose.
•
If the water pressure is greater than 8.6 bar, a pressure reducer must be installed in front of
the filter system.
•
When choosing the material for parts that come into contact with water after the BRITA filter
system, it is important to remember that, due to the process, decarbonised water contains
free carbon dioxide. For this reason, only materials that are compatible with free carbon dioxide
must be used. We recommend the use of BRITA hoses.
•
All parts must be installed in accordance with the country-specific guidelines on the installation
of drinking water facilities.
4 Installation
Caution: Prior to installation, read the technical data (Chapter 9) and the operating and safety
!
information (Chapter 3). After storage and transport below 0 °C, the product must be stored in the open
original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures
(Chapter 9) for operation.
4.1 Assembling the filter head, water connection
•
Close the water intake and switch off the power supply to the end device
A
•
Fit the wall mounting bracket
Caution: When fitting the bracket, note the installation dimensions, bending radii of
!
B
the hoses and dimensions of the accessories (e.g. BRITA FlowMeter). When using the
wall mount, install vertically only! The PURITY C1100 cannot be installed using the wall
mounting bracket.
•
Fit the hoses to the water inlet "IN"
C
•
Use flat seals for G3/8" connections. For John Guest connections, use hoses with
a diameter of 8 mm. In the case of John Guest connections, the two safety clips
be inserted after fitting the hose.
Caution: The tightening torque at G3/8" connections must not exceed 14 Nm!
!
Only hose connections with flat seals may be used, as hoses with conical screw
connections damage the connections on the filter head and invalidate any warranty
claim! We recommend the use of BRITA hoses.
•
When using PURITY C 0–70 % filter heads, check by-pass setting
D
the factory) and if necessary adjust this setting to the local carbonate hardness
(PURITY C Quell ST) (chapter 4.2).
•
When using PURITY C Steam filter heads, check by-pass setting
and if necessary adjust this setting (chapter 4.2).
•
Lock the filter head
* PURITY C Steam filter head is delivered without wall mounting bracket.
in the intended position.*
5
and outlet "OUT"
4
in the wall mounting bracket
1
on the filter head
3
1
(set to 30 % at
10
(set to 1 at the factory)
10
.
5
EN
.
must
12
21