Maintenance - ProFitter KFA400PF2 Manual De Instrucciones De Operación Y Lista De Partes

Calentadores de aceite
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ProFitter
Operating Instructions and Parts Manual
TM
Model KFA400PF2

Maintenance

Never service heater
WARNING
while it is plugged in
or while hot!
NOTE: USE ORIGINAL EQUIPMENT
REPLACEMENT PARTS. Use of third-
party or other alternate components
will void warranty and may cause
unsafe operating conditions.
UPPER SHELL REMOVAL
- Remove screws along each side and
top of heater using medium Phillips
screwdriver.
Figure 10 – Upper Shell Removal
FAN BLADES AND AIR DEFLECTOR
CLEAN EVERY SEASON OR AS NEEDED.
- Remove upper shell.
- Clean fan blades and air deflectors
using soft cloth moistened with
kerosene or solvent.
- Dry fan blades and air deflectors
thoroughly.
- Reinstall upper shell.
Air Deflector
Figure 11 – Fan Blades and Air Deflectors
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com
SPARK PLUG
CLEAN AND REGAP EVERY 600 HOURS
OF OPERATION OR REPLACE AS NEEDED.
- Remove upper shell.
- Remove spark plug wire from spark
plug (See Figure 12).
- Remove spark plug from burner head
using medium Phillips screwdriver.
- Clean and regap spark plug electrodes
to .140" (3.5 mm) gap.
- Reinstall spark plug into burner head.
Screw
- Attach spark plug wire to spark plug.
- Reinstall upper shell.
Upper Shell
Burner Head Spark Plug
Figure 12 – Spark Plug
Fan Blade
Spark Plug
Wire
Gap
7
NOZZLE
REMOVE DIRT IN NOZZLE AS NEEDED.
- Remove upper shell.
- Remove fuel line from solenoid valve
using 1/4" wrench.
- Remove spark plug wire from spark
plug.
- Remove spark plug from burner head
using medium Phillips screwdriver.
- Remove five screws using medium
Phillips screwdriver and remove burner
head from combustion chamber.
- Carefully remove nozzle from burner
head using 5/8" socket wrench.
- Blow compressed air through face of
nozzle (this will remove any dirt).
- Inspect nozzle for damage. If damaged
or clogged, replace nozzle.
- Make sure plug is in place on burner
head.
- Reinstall nozzle into burner head and
tighten firmly (175-200 inch-pounds).
- Reinstall spark plug into burner head.
- Attach burner head to combustion
chamber.
- Attach spark plug wire to spark plug.
- Attach fuel line to solenoid valve.
Tighten firmly.
- Replace upper shell.
Spark Plug
Burner Head
Nozzle
Plug
Figure 13 – Nozzle
Spark Plug
Wire
Fuel Line
Tabla de contenido