Ravaglioli RAV 1400 A Manual Del Usuario página 44

Elevador electrohidráulico
Tabla de contenido
9
9.
PROBLEMS
Some possible problems which may arise while using the lift are listed here below. Ravaglioli declines all responsibility for damages to people,
animals and objects caused by unauthorized staff. Moreover, if faults occur you are advised to contact the technical service assistance to
receive advice and information on how to carry out work and/or adjustments in maximum safety conditions, thus avoiding the risk of causing
damages to people, animals and objects.
Turn the main switch to "0" and lock in case of emergency and/or maintenance to the lift (RAV 1400 A - RAV 1400 B).
Technical assistance is required. Intervention by others prohibited.
PROBLEM
Machine not working
Machine carries out rise
movement but not descent
Descent is extremely slow
The motor is working
properly but the lift does
not rise
The motor is working
properly but the rise speed is
extremely slow
The pump does not prime
The pump blocks
under load
The pump works properly
but the oil does not reach
proper pressure
The pump does not reach
the max. pressure
The pump reaches
proper pressure but the
load does not move
The piston moves without
pressing the "RELEASE"
pedal
Insufficient pump capacity
when max. pressure is reached
44
CAUSE
a) Mains switch in "0" position
b) Transformer fuse or general
protective fuses broken.
c) Electric system faulty.
a) Descent solenoid valve faulty.
b) Obstruction under platform.
a) The capacity regulating valve is not
working properly.
a) The descent solenoid valve is
blocked in open position.
b) Pump suction filter blocked.
a) The descent solenoid valve
is partially open.
b) Pump suction filter
partially blocked.
c) Pump used or damaged.
d) Manual descent valve
partially open.
a) Compressed air line closed or
obstructed
a) Insufficient air pressure.
b) Air filter dirty or clogged.
a) Oil leakage in the main
hydraulic system.
b) Pump leakage.
c) Insufficient oil level.
a) Insufficient air pressure.
b) Inner safety valve not properly set
c) Oil leakage in the main
hydraulic system.
a) Excessive load.
b) Incorrect oil circulation.
a) Oil leakage in the main
hydraulic system.
b) Pump faulty
a) Insufficient air pressure.
b) Air filter dirty or clogged.
c) The tank has not been bled.
SOLUTION
a) Turn to position "I".
b) Replace used fuses.
If a fuse breaks again, find the
cause of the problem.
c) Check efficiency, components and
connections (push buttons, solenoid
starter, heat detector, transformer).
a) To lower the platform, see section 7.1.
b) Press rise button.
Remove obstruction.
a) See "Maintenance" section
a) See "Maintenance" section.
b) Clean filter.
a) See section on "Maintenance"
b) Clean filter.
c) Replace pump.
d) Restore valve seal.
a) Make sure compressed air is
delivered to the pump.
a) Make sure the pump feed pressure
(compressed air) is between 2.8 and 10 bar.
b) Clean or replace the air filter.
a) Check for oil leakage and repair,
if necessary.
b) Check for pump leakage and return
it to the Manufacturer for servicing.
c) Check for proper oil level and top up,
if necessary.
a) Make sure the pump feed pressure
(compressed air) is between 2.8 and 10 bar.
b) Contact the Manufacturer.
c) Check for oil leakage and repair.
if necessary.
a) Reduce load.
b) Make sure tubes are not throttled
and cylinder is not damaged.
a) Check for oil leakage and repair,
if necessary.
b) Check for pump leakage and
contact the Manufacturer
a) Make sure the pump feed pressure
(compressed air) is between 2.8 and 10 bar.
b) Clean or replace the air filter.
c) Bleed the tank.
0576-M001-0
RAV 1400 A - RAV 1400 AP
RAV 1400 B - RAV 1400 BP
Tabla de contenido
loading

Este manual también es adecuado para:

Rav 1400 apRav 1400 bRav 1400 bp

Tabla de contenido