PROTECTION
Safety features prevent the product from working, but are usually due to an operating error, an oversight on the part of the user or an environmen-
tal problem. The following table guides the user to solve the problem himself.
Icon at the onset of
safety
Torch missing
Unknown torch
Nozzle missing
No air
Pressure too low
Input overpressure
Overvoltage
Undervoltage
Missing phase
Retry
Trigger pressed
30
NEOCUT 105 / 125
Reminder icon
Meaning
Torch disconnected
Torch unrecognized
Dismantled nozzle
No air
Inlet pressure insufficient
Inlet pressure too high
If the above icons are displayed, cutting is forbidden but navigation in the HMI is still possible.
Thermal protection
Overvoltage
Under voltage
Phase missing
The arcpilot has not esta-
blished itself
Trigger pressed at start up.
Solutions
Connect a torch. If the problem persists when a torch is connected,
check the cables or replace the torch.
Connect a torch compatible with the product. If the problem per-
sists when a torch is connected, check the cables or replace the
torch.
Check that all consumables are present and screw the nozzle back
on.
Connect air and check compressor pressure.
Connect the compressed air, check the air connection used compati-
bility, check that the compressor is electrically powered.
The inlet pressure is higher than 9 bar.
Disconnect the air source, check the compressor pressure, lower
the compressor pressure. If necessary, add a pressure regulator
between the compressor outlet and the air inlet of the plasma cut-
ter.
Le poste est utilisé au-delà de son facteur de marche ou à une
température trop élevée ou dans un espace confiné. Laisser-le
poste se refroidir, améliorer son aération.
If the overvoltage or undervoltage is temporary, the plasma cutter
will restart by itself after 15 seconds of non-fault.
If this is not the case or if there is no phase, have the electrical
installation checked by an electrician.
This is probably due to the consumables, check their condition,
replace them if necessary. Try again
After 3 unsuccessful attempts, an error code will appear (E05 or
E06).
Release the torch trigger to continue.
If the trigger is not physically depressed, check the torch cables.