GYS NEOCUT 105 Manual Del Usuario página 29

Cortador al plasma trifásico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Press the torch trigger to start the arc while maintaining an angle of 30° to the
2
part. Slowly rotate the torch towards a perpendicular position (90°).
Immobilise the torch while keeping the trigger pressed. If the sparks come from
3
below the metal piece, the arc has cut the material.
Once the cutting has started, drag the pad slightly on the metal sheet to continue cutting. Try to maintain a regular rhythm.
4
GOUGING:
With the earth clamp fastened to the part, keep for torch at a 45° angle to the
1
piece, while maintaining the special gouging shield roughly 2mm away from the
part before starting the torch.
Press the torch trigger before starting the arc while maintaining it at an angle of
2
45° to the piece while cutting through the groove
Push the plasma arc in the direction you wish to cut. The distance between the
3
torch shield and the melted metal should be as little as possible in order to avoid
premature wear of the consumables or damage to the torch.
Speed
Torch-part
distance
CHANGING THE SHAPE OF THE GROOVE
Width
Depth
Increase the
Solutions
speed
NEOCUT 105 / 125
Angle
GROOVE SHAPE
You may modify the profile of the groove by adjusting the speed, the angle or the
distance of the torch on the metal piece, or the power output on the machine.
Increase the
Decrease the
Reduce the
torch-piece
speed
distance
Increase the
torch-piece
angle
distance
Reduce the
Increase the
Decrease the
angle
current
EN
current
29
Tabla de contenido
loading

Este manual también es adecuado para:

Neocut 125

Tabla de contenido