Craftsman CMCE520 Manual De Instructiones página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
Fig. E
To Turn on High-Volume
The high-volume hose is meant to be used for objects that
hold large amounts of air, such as air mattresses, rafts, and
swimming pool floats.
nOTE: The high-volume mode DOES NOT have an auto
shut-off feature.
1. Attach the high-volume hose 
pump inflator connection 
Volume Hose section.
2. Insert the high-volume hose 
into the object being inflated.
3. Press the high-volume side of the mode power
switch 
, indicated by the air mattress symbol.
 2 
4. To turn off, push the power switch to the center position.
To Turn on High-Pressure
The high-pressure hose is meant to be used for objects that
need more air pressure, such as tires and basketballs.
1. Remove the high-pressure hose 
2. Attach a nozzle as described in the Universal valve
adapter section.
3. Insert the nozzle into the object being inflated.
4. Press the high-pressure side of the mode power
switch 
 2 
, indicated by the tire symbol.
5. To turn off, push the power switch to the center position.
Deflate Using the High-Volume Hose
(Fig. A, F)

WARNING: Beware of objects being ejected.
When deflating, large amounts of air will exit the
high volume pump inflator connection 
the universal valve adapter is not pointed at anyone
or anything.
1. Remove the high-volume hose 
storage location.
2. Line up the hose end
with the high-volume pump
 24 
deflate connection
 11 
. Then, firmly slide in the hose so it
is securly in place.
3. Insert the hose, or it's tapered nozzle 
being deflated.
10
2
1
5
to the high volume
 7 
as described in the High
 12 
 7 
, or it's tapered nozzle 
 8 
 10 
from the storage.
 12 
. Ensure
 7 
from the
 8 
into the object
4. Press the high-volume side of the mode power
switch 
 2 
, indicated by the air mattress symbol.
5. To turn off, push the power switch to the center position.
6. To remove the hose, twist the hose counterclockwise
and slide hose off.
Fig. F
24
Setting the Automatic Shut-Off Pressure
(Fig. A)
nOTE: The digital readout will only show inflation pressures
when the inflator is being used. In both inflation and pump
mode the unit will show battery status.
1. To switch between the different units (psi, bar or kPa),
press the pressure mode/reset button 
required units are displayed.
2. Press the - or + pressure setting buttons 
required pressure is displayed.
3. After 3 seconds the display will flash and return to a
reading of "0.0". This is normal.
4. Connect the universal valve adapter
if required, to the item to be inflated, making sure that
the lever of the universal valve adapter is in the down
position to lock it in place.
5. To start the inflator press the mode power switch 
towards the side of the tire symbol.
6. When the item to be inflated has reached the preset
value the unit will automatically turn off.
nOTE: You may notice the actual pressure reading may
drop after a couple of seconds. This is normal.
7. To stop the inflator at any time, press the main power
button back to the center position.
nOTE: If the AC/DC power switch is turned off, all settings
will be lost and will need to be reentered. This is a safety
feature to prevent the risk of items OVER INFLATING.
Using the Inflator as a Pressure Gauge
1. Connect the universal valve adapter 
be checked.
2. Press the mode power switch 
symbol.
3. The digital readout will display the item's pressure.
7
11
 5 
until the
until the
 4 
9
and accessories,
 2 
,
 9 
to the item to
 2 
, on the side of the tire
Tabla de contenido
loading

Tabla de contenido