RESTORING THE ORIGINAL CONFIGURATION
Restoring the original configuration can be achieved in two ways, with the button
switch sequence:
from the OPENING position
Bring the rolling shutter to
the upper limit switch and
proceed as follows:
from the CLOSING position
Bring the rolling shutter to
the lower limit switch and
proceed as follows:
OR
with wired connection:
- Connect both the brown and black motor wires under the same switch, e.g. UP.
- Press the UP button for at least 2 seconds.
- Disconnect and then restore the original control switch electrical connections.
TM2 PP M
UP
UP
DOWN
DOWN
14
DOWN
UP
UP
UP
DOWN
DOWN
1- brown
2- black
3- blue
4-yellow-green
A4516_6G38_Rev.A
DOWN
UP