Emotron VSA 23 Manual Del Usuario página 41

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

VSA wiring diagram
Power terminal
1 phase 200 to 240 V
3 phase 380 to 480 V
PNP common point
Multi function digital
inputs
Accept DC 12/24V
signal
NPN common point
Multi-function
analogue input
10k
Set speed
PID feed back
input
Fig. 9
Wiring diagram
NOTE: Connect inputs to terminal 3 (internal 24 VDC) for PNP mode
(Positive switching), or to terminal 8 (common) for NPN mode (negative
switching).
NOTE: External 24 VDC may be used to supply the external contacts at each
input (connect the 0 V of the external supply to common (terminal 8)).
40
Wiring notes
L1(L)
L1
L2*
L3(N)
PE
(3)
24V
(4)
S1
(5)
S2
(6)
S3
(7)
S4
(8)
COM
(9)
10V
(10)
AIN
(11)
COM
(12)
FM
FM+
Braking
unit
T1
T2
T3
PE
(1)
RA
(2)
RB
21
S5
S6
24 V/0.6 A
IM
Multi-function digital output
1. SW1: Digital signal
selection (NPN/PNP)
2. SW2: Control signal
selection (0–10 V/4–
20 mA) V/I
Option interface
Multi-function on output
input card (2IN/1OUT)
Remote keypad
T+
T-
Emotron AB 01-3991-11r2
Tabla de contenido
loading

Este manual también es adecuado para:

Vsa 48

Tabla de contenido