Table 23
Menu Function Description
Deceleration stall-pre-
238
vention level (%)
Stall prevention decel-
239
eration time set
Main setup, Parameter set handling
241
Copy module
242
Factory default
Main setup, Trip Autoreset
251
Auto-restart times
Auto Restart for power-
252
loss
Main setup, Serial communication
VSD communication
261
address
262
Baud rate (bps)
263
Stop bit
264
Parity bit
265
Data bits
Communication time-
266
out detection
50
Programming instructions and menu list
Range/ Code
050 to 300
00.1 to 999 s
000: Copy module disable
001: Copy to module from VSD
002: Copy to VSD from module
003: Read/ write check
010: Reset to factory default (50 Hz)
020: Reset to factory default (60 Hz)
000 to 005
000: Enable
001: Disable
001 to 254
000: 4800
001: 9600
002: 9200
003: 38400
000: 1 Stop bit
001: 2 Stop bit
000: No parity
001: Even parity
002: Odd parity
000: 8 bits data
001: 7 bits data
00.0 to 25.5 Sec
Factory
Default
200
03.0
000
000
000
001
001
003
000
000
000
00.0