7. Wall Control Installation
3-WAY INSTALLATION
(One Fan Controlled by Two Different Wall Controls)
(See Figures 29 and 30).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box or circuit breaker panel before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
7.7
Disconnect Electrical Power to the Branch Circuit at
the Circuit Breaker Panel or Main Fuse Box before
attempting to install the Ceiling Fan Wall Control into
the Wall Box .
At All Wall Box locations remove Faceplates and
Screws from Existing Switches . Pull the Wall Switches
out from Wall Boxes and determine which Wall Box
contains the "HOT" Wire and which Wall Box contains
the "LOAD" Wire . Also, identify Traveler Wires which
are common to both Wall Boxes . Disconnect Wires from
Existing Wall Switches only .
NOTE: Do not attempt to disconnect any Wires not
already connected to Existing Wall Switches.
NOTE: Make all wiring connections using
wire connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
Before installing the First Wall Control, place the Wall
Control in "OFF" mode by pushing "ON/OFF" Switch
) to the "OFF" ( O ) position .
(
(Continued)
SW605
FAN/LIGHT
HOT
BLK
WALL
CONTROL
GROUND
TRAVELER
WIRE
NEUTRAL
RECEIVER LOCATED IN THE
CEILING COVER OF THE CEILING FAN
Figure 29
Install the First Wall Control in the Wall Box containing
the "HOT" Wire .
Connect the First Wall Control Black Wire labeled
"TO POWER SUPPLY" to the "HOT" 120V AC Supply
Source Wire . Securely connect the Wires with Wire
Connector, supplied (Figure 29) .
Connect the First Wall Control Black Wire labeled
"TO FAN" to the Traveler Wire(s) in the Wall Box and
secure with Wire Connector, supplied (Figure 29) .
Connect the First Wall Control Green Ground Wire
to the Supply Ground Conductor (this may be
a bare wire or wire with Green Colored insulation) .
Securely connect Wires with Wire Connector, supplied
(Figure 29) .
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
20
SECOND SW605
FAN/LIGHT
WALL
CONTROL
(Purchased
Separately)
GROUND
LOAD
BLACK
GROUND
RECEIVER LOCATED IN THE
SWITCH HOUSING ASSEMBLY
WARNING