Honeywell GLG Serie Instrucciones De Instalación página 12

Installation Instructions for
MICRO SWITCH GLS Limit Switches
Figure 10. Head Code: C
Roller Plunger Cam Actuation
Per EN50041 Operating Characteristics
Notes:
Free position, operate point, overtravel, and pretravel all to
EN50041
Refer to page 5 for instructions on how to read operating
characteristics and specifications
Catalog
listing
Contact block diagram
SNAP-ACTION CONTACTS
SINGLE POLE
GL**01C
GL**07C
SLOW ACTING BREAK
BEFORE MAKE
GL**03C
GL**33C
SLOW ACTING MAKE
BEFORE BREAK
GL**04C
GL**34C
SLOW ACTING
GL**05C
GL**35C
SLOW ACTING
GL**06C
GL**36C
GL**20C
GL**22C
GL**24C
GL**32C
GL**21C
STEP 1
GL**25C
GL**28C
GL**31C
STEP 2
12 sensing.honeywell.com
Nominal travels and related terminals
Contact Closed
**Positive Opening to IEC 947-5-1
0
21-22
13-14
Zb
0
21-22
13-14
Zb
0
21-22
13-14
Zb
0
13-14
23-24
2X
0
21-22
2Y
13-14
0
11-12, 21-22
SNAP ACTION
CONTACTS
13-14, 23-24
DOUBLE POLE
0
11-12
SNAP ACTION
13-14
CONTACTS
21-22
DOUBLE POLE
23-24
SEQUENCIAL
44,0 mm
[1.73 in]
Contact Open
Diff. Travel
15 18.3**
>
<
1.8 Differential travel
15**
>
<
16.8
16.8**
>
<
15
16.8
>
<
15**
>
<
15 18.3**
>
<
1.8 Differential travel
16.9
15
>
<
>
<
1.4 Differential travel
1.4 Differential travel
ISSUE 5
15,0 mm [0.59 in]
20,0 mm
Differential travel
[0.79 in]
10,9
,43
30°
Ø12,7 mm
[Ø0.50 in]
9,3 N
15,6 N
0,17 M/S
[2.1 lb]
[3.5 lb]
[6.7 in/S]
9,3 N
15,6 N
0,17 M/S
[2.1 lb]
[3.5 lb]
[6.7 in/S]
9,3 N
15,6 N
0,17 M/S
[2.1 lb]
[3.5 lb]
[6.7 in/S]
9,3 N
15,6 N
0,17 M/S
[2.1 lb]
[3.5 lb]
[6.7 in/S]
9,3 N
15,6 N
0,17 M/S
[2.1 lb]
[3.5 lb]
[6.7 in/S]
9,3 N
21,4 N
0,17 M/S
[2.1 lb]
[4.8 lb]
[6.7 in/S]
9,3 N
0,17 M/S
n/a
[2.1 lb]
[6.7 in/S]
81501
Operate point
58,0 mm
[2.28 in]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
1,7 mm/S
250
[0.067 in/S]
loading

Este manual también es adecuado para:

Gla serieGlf serieGls-din serie81501