Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Motion Sensor Light
Control
Model 1800
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
Lamp Holders
Cover
Plate
Sensor
Light Control
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with a junction box
marked for use in wet locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at home centers
and electrical supply stores.
© 2012 HeathCo LLC
4 Mounting
Screws (2 sizes)
Gasket
2 Wire
Connectors
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
10 Minutes
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the
10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day Night
x
/
minutes for
1
2
TEST
ON-TIME
10
AUTO
ON-TIME
10
TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
10 minutes
Flip light switch off
for one second then
back on*
203621-02A
x
x
x
TEST
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith HZ-1800-WH

  • Página 5: Detector De Movimiento Y Control De Luz

    FUNCIONAMIENTO Modalidad: A tiempo: Trabaja: Día Noche Prueba 5 segundos Detector de Autom. 10 minutos Manual Hasta el Movimiento y amanecer* *Se pone en Automático al amanecer. Control de Luz Nota: Cuando lo prenda por primera vez espere 1 minutos para que el circuito se calibre. Modelo 1800 Para PRUEBA: ON-TIME...
  • Página 6: Instalacion

    INSTALACION Conecte el Control de Luz Para una fácil instalación escoja una luz con un ADVERTENCIA: Apague la energía en el fusible interruptor de pared. o cortacircuitos. Para un mejor funcionamiento, instale el aparato a casi 2,4 m del suelo. ❒ Quite el aparato de luz existente.
  • Página 7: Especificaciones

    PRUEBA Y AJUSTE ❒ Afloje el tornillo sujetador en la Tornillo unión esférica y gire despacio Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. el detector. ❒ Fije el control de DURACIÓN (ON-TIME) a la posi- ❒ Camine por el área a prote- Unión ción de PRUEBA.
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se en- 1. El interruptor de luz está apaga- La luz se 1. Un faro está colocado demasiado cerca ciende. queda al detector o apunta a objetos cercanos prendida 2.