INSTALLATION
Note: All wiring must be run in accordance with the
National Electrical Code through conduit or another ac-
ceptable means. Contact a qualified electrician if there
is any question as to the suitability of the system.
WARNING: Turn power off at circuit breaker or
fuse. Place tape over circuit breaker switch and
verify power is off at the fixture.
1. Remove the existing light fixture (if necessary).
2. Insert the junction box wires through the center of
the mounting bracket.
3. Attach the mounting bracket to the junction box us-
ing the short bracket screws. Note: Ensure the long
fixture screws are horizontal before tightening the
bracket to the junction box.
Mounting Bracket
Short
Bracket
Screw
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Use a green ground "pigtail" (not provided) and twist
one end together with the bare fixture wire and the
box ground wire. Secure with a wire connector. Secure
the other end of the "pigtail" with the GND screw on
the mounting plate.
Junction Box
If you have metal junction box, you may not need the
green "pigtail". If you are unsure about the grounding
method, consult your local building code.
Ground Screw
Long Fixture Screw
2
WIRING

Recommended Grounding Method

White to white
Black to black